广西师范大学学报(自然科学版) ›› 2017, Vol. 35 ›› Issue (2): 108-111.doi: 10.16088/j.issn.1001-6600.2017.02.016

• • 上一篇    下一篇

超敏化学发光液稀释法降低蛋白印迹的发光强度

范才文, 唐娟, 罗琴, 李璐, 向秋*   

  1. 桂林医学院科学实验中心,广西桂林541004
  • 出版日期:2017-07-25 发布日期:2018-07-25
  • 通讯作者: 向秋(1965—),男,湖南洞口人,桂林医学院教授,博士。E-mail:guilin996@163.com
  • 基金资助:
    国家自然科学基金(81260344);广西自然科学基金(2013GXNSFAA019228);广西壮族自治区教育厅资助项目(LX2014274)

Reduced Light Intensity of Western Blot by Diluted Ultra-enhancedChemiluminescent Solution

FAN Caiwen, TANG Juan, LUO Qin, LI Lu, XIANG Qiu*   

  1. Science Experimental Center, Guilin Medical University, Guilin Guangxi 541004, China
  • Online:2017-07-25 Published:2018-07-25

摘要: 蛋白印迹(western blot)分析是根据抗原、抗体特异性结合的原理检测复杂样品中某蛋白的技术。然而当样品中的蛋白浓度过低,特别是目标蛋白为低丰度蛋白时,采用普通化学发光检测,有时出现蛋白条带发光弱,曝光不够,而采用超敏化学发光检测则出现蛋白条带发光强,曝光过度,两者的蛋白条带显影图像均不理想。本文将超敏化学发光液稀释后再检测,显影效果显著提高,蛋白条带图像清晰,可见超敏化学发光液稀释法降低蛋白印迹的发光强度,提高了蛋白条带的显影效果。

关键词: 蛋白印迹, 超敏发光液, 化学发光, 稀释

Abstract: Based on specific binding of antigen and antibody, western blot analysis is used to detect a protein in complex samples. However, using conventional chemiluminescence detection, light of the protein band is weak and X film is not much exposed, and using ultra-enhanced chemiluminescence detection,light of the protein band is strong and X film is too much exposed, both development images of protein band are not ideal sometimes, when protein concentration of the samples is too low, especially when the protein to be detected is lower abundant in X film is samples. Therefore, the protein was detected with diluted ultra-enhanced chemiluminescent solution, and the protein band was clearly showed and the development image effect of protein bands was improved obviously, which indicates that the intensity of light emission could be reduced and the development image effect of the protein bands could be improved by dilution of ultra-enhanced chemiluminescent solution in western blot analysis.

Key words: western blot, ultra-enhanced chemiluminescent solution, chemiluminescence, dilution

中图分类号: 

  • R446.6
[1] 牟宏宇, 罗波, 何涛. Western blotting 中低丰度蛋白转膜方法改进[J]. 泸州医学院学报, 2014, 37(5):472-475.
[2] 张莉萍, 蒋纪恺, JOE T. Western-blot 检测蛋白表达的方法改进及初步应用[J]. 第三军医大学学报,2001,23(10):1242-1243.
[3] ZANGHERI M,DI N F,MIRASOLI M, et al. Chemiluminescence lateral flow immunoassay cartridge with integrated amorphous silicon photosensors array for human serum albumin detection in urine samples[J]. Analytical and Bioanalytical Chemistry,2016, 408(30):8869-8879.
[4] 高重天, 孙群. 如何正确估计蛋白质SDS聚丙烯酰胺凝胶电泳的样品加样量[J]. 生物学通报,2009,44(3):54.
[5] D’SOUZA A, SCOFIELD R H. Protein stains to detect antigen on membranes[J]. Methods in Molecular Bioloby,2009,536:433-440.
[6] LIU J, ZHANG L, FU C, et al. Employment of 4-(1,2,4-triazol-1-yl)phenol as a signal enhancer of the chemiluminescent luminol-H2O2-horseradish peroxidase reaction for detection of hepatitis C virus in real samples[J]. Luminescence, 2015, 30(8):1297-302.
[7] 张纪磊. 化学发光共振能量转移体系的研究及其在肿瘤标志物检测中的应用[D]. 青岛:青岛科技大学, 2011.
[1] 吴卓玲,赖艳花,杨柳. 不同固定剂对核膜蛋白免疫荧光效果的比较研究[J]. 广西师范大学学报(自然科学版), 2018, 36(1): 121-125.
[2] 庄枫红, 马姜明, 陈丽婷, 苏静, 张雅君, 于方明. 中华水韭对不同pH处理的生理生态响应[J]. 广西师范大学学报(自然科学版), 2017, 35(2): 133-141.
[3] 霍群, 刘杰, 陈莉, 廖维甲. 血清AFP临界值判断对肝癌诊断的影响[J]. 广西师范大学学报(自然科学版), 2014, 32(3): 121-124.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!
版权所有 © 广西师范大学学报(自然科学版)编辑部
地址:广西桂林市三里店育才路15号 邮编:541004
电话:0773-5857325 E-mail: gxsdzkb@mailbox.gxnu.edu.cn
本系统由北京玛格泰克科技发展有限公司设计开发